One entry per sizing engine version. The version moves only when the numbers for the same input move.

main has no version constant yet: responses carry engine.engine_revision (the Cloud Run revision). SIZING_ENGINE_VERSION and engine.version arrive with SAVINGS-CURVE, which rebases on top of these entries and renumbers to 1.12 (ruling R2, 2026-10-28). The git tag engine-vX.Y is cut on the SHA that ships.


1.11 — Tariff-aware fixed timer (November 2026)

Card f-0132. Tag engine-v1.11 on 1cdde161.

What was wrong

Every sizing reports two savings figures: the fixed timer (savings_static) and WattChop Drive (savings_optimized). The timer used the same hard-coded windows on every tariff: discharge in hours 16–20 and charge from the grid in hours 0–5. On a tariff whose expensive or cheap hours fall elsewhere, the timer was scored on windows a real time-of-use timer would not use.

What changed

From commit 1cdde161:

What it does to the numbers

Timer savings move. Drive savings do not (see below), so the uplift of Drive over the timer moves by the timer's change.

Goldens, engine-v1.10 → 1.11 (fixed hardware, run locally, nothing stored), annual timer savings:

Release check on the live app, 2026-11-21: tools/partner_release_check.py on the sandbox key against revision wattchop-app-01717-rwp, which was deployed from main at d6d862b1 and so contains 1cdde161. The three flat-load cases are the test a partner reported in 1.10, here battery only (pv_kw 0). The fourth is a sweep on a synthesized Daytime Office load. The synchronous sizing response carries no run_id, so those rows read n/a. Money columns are annual USD.

caserun_idengine_revisionpv_kwbattery_kwhtimer savings (savings_static)Drive savings (savings_optimized)upliftpeak kW without → with Drive
flat 100 kW +15 kW 1 h on the 15th (B-10-S, 180 kWh / 2 h, pv 0)n/awattchop-app-01717-rwp01803,389.453,794.66405.21115.00 → 103.50
flat 100 kW +30 kW 1 h on the 15th (B-10-S, 180 kWh / 2 h, pv 0)n/awattchop-app-01717-rwp01805,045.877,485.652,439.78130.00 → 104.00
flat 100 kW +60 kW 1 h on the 15th (B-10-S, 180 kWh / 2 h, pv 0)n/awattchop-app-01717-rwp01806,117.2414,776.628,659.38160.00 → 104.00
Daytime Office sweep (40,000 kWh/month, B-10-S)44356ddc-01ce-4b7c-9323-703271d56fcdwattchop-app-01717-rwp30050091,335.23110,601.5019,266.27166.32 → 130.60

What did not move

Known limits


1.10 — Single-window fine target (October 2026)

Charter: CHARTER_SINGLE_WINDOW_FINE_TARGET.md. Reported by a partner (2026-10-23).

What was wrong

On tariffs where demand is billed over all hours (PG&E B-10 and every 24-hour-only demand schedule), the engine picked each month's demand target from a ladder in 5 %-of-peak steps. When the base load sat between two rungs, the target stopped at the rung above it. A flat 100 kW load with a 15 kW spike was shaved to 103.5 kW, not 100 kW. Tariffs with more than one billed window already had a 1 % polish (engine-v1.9, M4); single-window tariffs never got one.

What changed

What it does to the numbers

The residue is closed in months where shaving to the base lowers the bill. In B-10 summer the engine keeps today's target, because the arbitrage it would give up is worth more than the demand gain.

A partner's own runs (B-10 S, 180 kWh / 2 h, flat 100 kW load with a one-hour spike on the 15th), replayed from their stored loads with the same arguments as the API:

RunSpikePeak cut per month, 1.9Peak cut per month, 1.10Annual savings, 1.9Annual savings, 1.10
b201c34f+15 kW12.000 kW13.720 kW$3,881.68$4,156.01
cd0ec22a+30 kW26.442 kW28.378 kW$7,521.51$7,830.85
6edfe2aa+60 kW56.350 kW58.478 kW$14,872.35$15,206.16

These runs sent pv_kw: 1.0 with no site, so 1 kW of solar was modelled at the default test site (Ventura) and adds ~0.56 kW to every cut above. engine-v1.9 reproduces a partner's reported 12.000 / 26.442 / 56.350 exactly. Battery only (pv_kw: 0): 11.5 → 13.8, 26.0 → 28.6, 56.0 → 58.1 kW.

Month by month (battery only, +15 kW): January–May and October–December go from 103.5 to 100.05 kW. June–September stay at 103.5 kW.

Flat-load grid, B-10 S, 2 h (annual bill, engine-v1.9 → 1.10):

Base / battery+15 kW+30 kW+60 kW
100 kW / 180 kWh−$360.88−$407.85−$334.74
50 kW / 180 kWh−$203.92−$167.38−$460.27
200 kW / 180 kWh−$350.81−$721.90−$816.01
100 kW / 90 kWh−$360.95−$408.00−$785.10
100 kW / 360 kWh−$360.88−$407.86−$334.74

What did not move

Known limits